Such a whole house HRV unit shall be selected that enables air flow control. The need for ventilation is different in various weekdays. A building shall be ventilated even when nobody is in, although at a lower degree. For an empty building, its air volume shall be exchanged about once in 6 hours, under current use it is about once in two hours, and a boost mode shall ensure air exchange in less than one hour. This means that the max. hourly performance of a HRV unit should be at least equal to the volume of the ventilated area.

Beside large whole house HRV units also single room HRV units can be used for individual rooms.

CodeName
7483HR 100R - Residential Heat Recovery Ventilation Unit

Airflow rate: 77 m3/h

HR 100R - Residential Heat Recovery Ventilation Unit
10308HR 100RS - Residential Heat Recovery Ventilation Unit

Airflow rate: 77 m3/h, installation in a ceiling void.

HR 100RS - Residential Heat Recovery Ventilation Unit
10176Sentinel Kinetic B Residential Heat Recovery Ventilation Unit

Max. airflow rate 275 m3/h, for a single-family house of up to 200 sqm living area

Sentinel Kinetic B Residential Heat Recovery Ventilation Unit
10335Sentinel Kinetic B Plus Residential Heat Recovery Ventilation Unit

Max. airflow rate 490 m3/h, for a single-family house of up to 350 sqm living area

Sentinel Kinetic B Plus Residential Heat Recovery Ventilation Unit